Orders placed by 14:00 on a business day leave Poland the same day. Free shipping from €100
Product question?Write to us
RUO

All products are chemical reagents for scientific research only. Not for consumption or use in humans or animals. Policy

Quality and lot release

Before a lot is released

Nothing is released on a label alone. Every lot is released against a purity specification of 99% or higher, measured by reversed phase HPLC, with identity confirmed by mass spectrometry. The vial is then checked by eye and packed only if the seal is intact.

Four checks, in plain terms:

  • Chromatographic purity. The lot is run by reversed phase HPLC and the result has to meet the specification of 99% or higher.
  • Identity. Mass spectrometry confirms that the material is the compound named on the label.
  • Appearance. The contents are looked at before packing, as lyophilised material in a sealed vial, or as a solution for the solvents.
  • Seal. The closure is checked, and a vial that is not intact is not shipped.

What the purity figure is a percentage of

A chromatographic purity figure is a proportion of peak area. The sample is separated by reversed phase HPLC and the detector response across the run is integrated. Purity of 99% or higher means the peak for the target compound accounts for at least that share of the total integrated peak area under the method used.

So the figure answers one question: of everything the method detects and separates, how much is the compound you ordered.

Identity by mass spectrometry answers a different question. It confirms what the compound is. It does not say how much of the vial it is.

What the figure does not cover

Worth being clear about, because a single number is easy to over read:

  • It is not net peptide content by mass. Water, counter ions and residual salts do not appear as peaks to be counted, so the figure is not a statement about how many milligrams of peptide a vial holds. If you are working out a concentration, the concentration calculator does the arithmetic from the numbers you enter.
  • It says nothing about sterility and nothing about endotoxins.
  • Anything the method does not retain or detect is not in the figure. A purity figure is always a figure under a stated method.
  • It says nothing about what happens after the vial leaves us. Storage, reconstitution and handling in your laboratory are your conditions, not ours.

Documentation for a lot

Documentation is retained for each lot and is available on request against the lot number printed on the vial. Write to help@difania.eu with that number and the document set held for the lot is sent back to you.

Two practical notes. Keep the lot number until the work is finished, because the number is how the document set is found. And if your institution wants paperwork in hand before material arrives, ask before you order, not after.

What we do not claim

We do not test for sterility. We do not test for endotoxins. We claim no certification of any kind unless it is listed on the documentation for that specific lot, and if a check is not named there, it was not performed.

We also grade nothing for use in a person or an animal, because nothing here is sold for that. Everything in the catalogue is a reagent, under the condition of sale set out on the research use only page. Anything still unclear goes to the contact page.

What does a purity of 99% or higher actually mean?

It is a chromatographic figure. The lot is separated by reversed phase HPLC and the detector response is integrated, so the figure says that the peak for the target compound accounts for at least 99% of the total integrated peak area under the method used. It is a proportion of what the method detects and separates, not a proportion of the weight in the vial.

How do I get the analytical documentation for my lot?

Write to help@difania.eu and give the lot number printed on the vial. Documentation is retained for each lot and is sent on request against that number. Without the number we cannot tell which document set belongs to your material, so keep the vial or a note of the number until your work is finished.

Is the material sterility tested or endotoxin tested?

No. We do not test for sterility and we do not test for endotoxins, and we make no claim about either. The release checks cover chromatographic purity, identity, appearance and the seal. Nothing in the catalogue is supplied for use in humans or animals.

What if a check I need is not named in the documentation?

Then treat it as not performed. We claim no certification of any kind unless it is listed on the documentation for that specific lot. If your work depends on a particular check, ask for the documentation before you order rather than after the parcel arrives, so you can see what is held for that lot.