Orders placed by 14:00 on a business day leave Poland the same day. Free shipping from €100
Product question?Write to us
RUO

All products are chemical reagents for scientific research only. Not for consumption or use in humans or animals. Policy

Checklist

Checklist: equipment and consumables for a peptide bench

17 November 2026 · 5 min read

This is what a bench handling lyophilised peptides needs in place before the first vial is opened, grouped by what each item is for. None of it is exotic. It is worth writing down because a missing item is usually discovered halfway through a procedure, with an open vial and no good way to pause.

Handling and transfer

Item Why it is there What goes wrong without it
Adjustable pipettes covering your working range the only practical way to measure microlitre volumes volumes get estimated, and an estimated volume makes every concentration downstream approximate
Low retention tips peptide adsorbs onto plastic surfaces the delivered volume is correct and the delivered mass is not, worst in dilute solutions
Low binding polypropylene tubes same problem, over much longer contact losses show up as a slow drift between an early and a late experiment
A bench rack that holds tubes upright tubes do not stand on their own a tube on its side puts liquid against the cap, and caps are not seals
Lint free wipes fibres end up in solution a wipe that sheds leaves material you will later mistake for a problem with the peptide
Ethanol or isopropanol for wiping stoppers and surfaces standard before piercing or opening a closure contamination introduced at the one step that was supposed to be clean

Keep one type of tube and one type of tip across a whole series. When two results disagree, you do not want the consumable to be one of the variables.

Measurement

Item Why it is there What goes wrong without it
A balance with a draught shield, resolution matched to the mass air movement shifts a reading at the milligram level the number drifts while you watch, so you record whatever was on screen when you looked up
Check weights and a calibration schedule a balance can be precise and wrong consistent results that are consistently off, which is the hardest error to notice
Graduated cylinders or volumetric flasks solvent volumes in the millilitre to litre range are not pipette work made up volumes that are near enough, which is not the same as known
pH strips or a meter relevant wherever an acidic solvent is used you cannot say afterwards what the solution actually was
A timer steps have durations “about ten minutes” varies by person and by how busy the day is

The concentration calculator covers the arithmetic between vial size, volume and concentration.

Storage

Item Why it is there What goes wrong without it
A freezer holding minus 20 degrees Celsius long term storage of portions there is nowhere to keep a divided vial, so the whole vial gets thawed repeatedly
A rack or box that actually fits the freezer shelf a box that does not fit never goes in properly tubes end up loose in the door, where the temperature cycles every time somebody opens it
A fridge at 2 to 8 degrees Celsius short term storage and unopened stock material sits at room temperature because there is no obvious place for it
Cryo boxes with a grid, plus a written map a grid turns a search into a coordinate every retrieval means lifting out forty tubes and warming all of them
A minimum and maximum thermometer or a data logger a failure that recovered looks exactly like no failure at all an overnight excursion passes unnoticed and is never connected to the odd results that follow
Equipment Target
Freezer for portions -20 °C
Fridge for solvents and unopened stock 2 to 8 °C

Labelling and records

  • Labels with freezer rated adhesive. Ordinary labels lift at a corner and are loose in the box within weeks.
  • A marker that survives frost and solvent. Whiteboard ink is designed to come off, and it does, usually on a glove.
  • A bound notebook kept at the bench. A log written up later is written from memory, and memory reports the intended volume.
  • A printed map inside each box lid. Without it, the only index of the box is the person who filled it.

Protection

  • Nitrile gloves, changed when contaminated, both to protect you and to keep skin off the work.
  • Safety glasses. Glass under vacuum, cold glass and pressurised closures all fail towards your face.
  • A lab coat kept in the room, so what is on it stays in the room.
  • Ventilation or a fume hood wherever volatile or corrosive solvents are opened, including acetic acid in water.
  • An eye wash within reach, meaning reachable with your eyes shut, which is the only way you will reach it.
  • Absorbent pads and a spill kit, so a spill is contained rather than spread by somebody fetching paper towels.

Waste

  • A rigid, closed container for broken glass and spent vials. Glass in a soft bag injures whoever carries the bag.
  • A labelled, closed container for solvent waste, never an unmarked beaker. An unlabelled container is a problem nobody can safely resolve later.
  • Disinfectant and a written surface procedure, so decontamination does not depend on who is on shift.
  • Bags for used consumables, kept at the point of use rather than across the room.

What tends to be missing

The absent item is rarely the expensive one. It is the rack that does not fit the shelf, the marker that wiped off, the tips that were not low retention, the box with no map. Each costs little and each quietly damages a result nobody can explain afterwards.

All of it is ordinary laboratory stock, and the list is easier to check against an empty bench than against an open vial.