Quality control
Reference: what a certificate of analysis tells you
8 November 2026 · 5 min read
A certificate of analysis records what was measured, on one lot, by one laboratory, on one date. It is not a guarantee about the vial on your bench. Read that way it is useful. Read as a quality badge it misleads. This note takes the sections in turn, and then what the document leaves unanswered.
The sections, line by line
| Line | What it reports | What to check |
|---|---|---|
| Product identification | name, catalogue reference, formula, molecular mass | it matches the vial and your order |
| Lot number | the batch the tested sample came from | it matches the vial exactly |
| Appearance | what the analyst saw, commonly a white to off white cake | your vial looks like the description |
| Purity | the method used and the figure obtained | which method, and a percentage of what |
| Identity | the method, observed against expected | an identity test is there at all |
| Water content | residual water, where measured | whether it is reported or absent |
| Storage | the condition the material needs | your storage matches it |
| Date of analysis | when the testing was done | how old the measurement is |
Purity: a percentage of what
Chromatographic purity is normally determined by reversed phase high performance liquid chromatography and reported as an area percentage. The sample is separated on a column, a detector records what comes off, and the peak of interest is given as a share of the total area.
Three limits follow.
It is relative, not absolute. The figure says how much of the detected signal belongs to the main peak. It does not say what fraction of the powder in the vial is the substance.
It counts only what the detector sees. Detection in the low ultraviolet region responds to the peptide bond, so a salt, a counter ion or residual water contributes nothing to the chromatogram while contributing fully to the mass you weigh out.
It counts only what elutes. Anything retained on the column under the stated conditions is absent from the total.
This is why chromatographic purity and net peptide content are different quantities. Net content, where it is reported at all, accounts for the non peptide fraction: counter ions, residual solvent and water. A vial can be high in chromatographic purity and still hold less substance by mass than its nominal quantity. If your work depends on the amount rather than the identity, that is the distinction that matters.
Identity: what the method proves
Identity is usually confirmed by mass spectrometry, comparing the observed molecular mass against the mass calculated from the expected formula. A match is good evidence that you have a molecule of the right composition.
It is weaker evidence about arrangement. Different arrangements of the same atoms share a mass, so a sequence is established by tandem mass spectrometry or by sequencing, not by a single figure. A certificate reporting an observed mass has shown consistency with the expected structure, no more.
Water content
Residual water is measured by Karl Fischer titration, or estimated by loss on drying. It matters twice over. It is part of the mass you weigh but not part of the substance, so it affects any calculation starting from a weighed mass. And water left in a lyophilised solid bears on how the material behaves in storage.
Where water content is not reported, nothing has been established about it. The absence of a line is not a result.
What the certificate does not tell you
This is the half that gets skipped.
- Nothing about your vial beyond its lot. The analysis was done on a sample drawn from the batch, not on the vial in your hand.
- Nothing about what happened afterwards. Transit temperature, a seal that failed, time on a bench, cycles in and out of a freezer: all of it came after the date of analysis.
- Nothing about the future. A measurement on a date says nothing about the condition of the material a year later.
- Nothing about sterility or endotoxin unless those tests are listed with their methods and results.
- Nothing about suitability. A certificate describes a chemical. It says nothing about whether the material fits your protocol, and makes no claim about use in any living system. Our terms are set out under research use only.
- Nothing the methods were not asked to find. Impurities outside a method’s range go unreported because they were never sought.
The lot number is the thread
Every other field is meaningful only because the lot number ties it to a physical batch. The lot connects the document to the vial, the vial to your weighing record, and that record to a result you may need to defend or repeat.
Three habits keep the thread unbroken.
- Record the lot number at goods in, on the vial and in the log, not from memory afterwards.
- Carry it into every record downstream: the aliquot label, the notebook page, the data file.
- Note where a series changes lot. Batch to batch variation is ordinary. An unexplained shift in results that coincides with a change of lot is a question you can only ask if you wrote the lots down.
Filing the certificate is not enough. A certificate with no link to the vial it describes is an orphan document, and an unlabelled vial with a perfect certificate in a folder is still unusable material.
Documentation per lot is described under quality, and the terms above in the glossary.