Reference
Reference: concentration, volume and molarity for a vial
5 November 2026 · 5 min read
Almost every number a laboratory writes on a tube comes from one relationship and three rearrangements of it. The arithmetic is simple enough that it is usually done in someone’s head, which is exactly why it is worth writing down once, with the units attached. Most concentration errors are not mistakes in algebra. They are factors of a thousand.
One relationship, three ways round
Concentration is mass divided by volume. Everything else follows:
- Concentration = mass divided by volume. A 10 mg vial made up in 5 ml gives 2 mg/ml.
- Mass = concentration multiplied by volume. 0.4 ml of a 2 mg/ml stock contains 0.8 mg.
- Volume = mass divided by concentration. To reach 1 mg/ml from a 5 mg vial, add 5 ml.
The third form is the one used at reconstitution: you know the mass in the vial, you choose the concentration you want, and the arithmetic hands you the volume to add. The concentration calculator does all three if you would rather not do them by hand.
Units that cause trouble
| This | Equals this |
|---|---|
| 1 mg/ml | 1 g/l |
| 1 mg/ml | 1000 µg/ml |
| 1 mg/ml | 1 µg/µl |
| 1 mg/ml | 0.1 % weight per volume |
| 1 ml | 1000 µl |
| 1 mM | 1 µmol/ml |
| 1 mM | 1 nmol/µl |
The pairing worth memorising is mg/ml and µg/µl. They are numerically identical, which means a figure written in one can be read in the other without any conversion. It also means that a tube labelled only with a bare number is ambiguous in a way nobody notices until it matters.
From mg/ml to a molar concentration
A molar concentration counts molecules rather than mass, and to count molecules you need the molecular mass of the substance, in grams per mole. It is on the product documentation. Do not estimate it.
The conversion is division:
Concentration in mol/l = concentration in g/l divided by molecular mass in g/mol
In bench units that becomes a shortcut worth remembering:
Concentration in mM = (concentration in mg/ml multiplied by 1000) divided by the molecular mass
Worked example. A 5 mg vial is made up in 2.5 ml, giving 2 mg/ml. The molecular mass of the substance is 2000 g/mol. Then (2 multiplied by 1000) divided by 2000 gives 1 mM.
The same arithmetic for a round 1 mg/ml stock across a range of molecular masses:
| Molecular mass (g/mol) | 1 mg/ml equals |
|---|---|
| 500 | 2 mM |
| 1000 | 1 mM |
| 1250 | 0.8 mM |
| 2000 | 0.5 mM |
| 2500 | 0.4 mM |
| 4000 | 0.25 mM |
| 5000 | 0.2 mM |
Read the table the other way and it is just as useful: for a fixed mass concentration, the larger the molecule, the fewer molecules you have. Two reagents at the same mg/ml are not at the same molar concentration unless their molecular masses happen to match.
Diluting a stock
One equation covers every dilution: the amount of substance you take out of the stock is the amount that ends up in the new tube.
Starting concentration multiplied by starting volume = final concentration multiplied by final volume
Rearranged for what you actually need, which is how much stock to take:
Volume of stock = (final concentration multiplied by final volume) divided by the starting concentration
Worked example. You have a 5 mg/ml stock and want 2 ml at 0.5 mg/ml. Volume of stock = (0.5 multiplied by 2) divided by 5, which is 0.2 ml. Add 1.8 ml of diluent to reach a final volume of 2 ml.
Note the order of that last sentence. You add 1.8 ml of diluent to 0.2 ml of stock to make 2 ml in total. You do not add 2 ml of diluent. Writing the final volume rather than the added volume on the protocol removes the ambiguity for whoever runs it next.
A dilution series
A tenfold series is the usual shape: take one part and add nine parts of diluent at every step. Starting from 2 mg/ml, the series runs 2, then 0.2, then 0.02 mg/ml and so on.
Three habits keep a series honest:
- Mix thoroughly at each step before taking the next aliquot. An unmixed step propagates into every tube after it.
- Change the tip at every step. A tip carries liquid on the outside as well as the inside.
- Keep the volume transferred reasonably large. A series built on 10 µl transfers carries far more relative pipetting error than one built on 100 µl transfers, and the error compounds down the row.
What goes wrong
- A factor of a thousand. Micrograms read as milligrams, or microlitres as millilitres. Write the unit next to every number, including on intermediate working.
- Volume added treated as final volume. The dissolved solid occupies volume too. For a few milligrams in millilitres the difference is negligible, but for precise work the volume is made up to a mark rather than added to a vial.
- The mass on the label taken as net substance. Material supplied as a salt carries counterions and residual water, so the net content can be lower than the weighed mass. Where that matters, the figure to use is the one on the documentation, not the nominal vial size. The glossary explains the terms that appear there.
- Rounding too early. Round once, at the end, on the number you will actually pipette.
- A tube labelled with a number and no solvent. The concentration is only half of what makes a result reproducible.
Checklist
- Units written beside every number.
- Molecular mass taken from the documentation, never estimated.
- Final volume stated on the protocol, not the added volume.
- Mixing and a fresh tip at every step of a series.
- Stock concentration, solvent and date on every tube.