Protocol
Protocol: planning quantities for a series of experiments
12 November 2026 · 5 min read
Most orders are placed forwards: somebody opens the catalogue, picks a vial size that sounds about right, and finds out later whether it was. Planning backwards takes ten minutes and answers a different question, which is how much material the work actually consumes and in what pattern over time. The second part decides which vials to buy.
Work backwards in five lines
- Volume per run. How much working solution one run consumes, at the concentration the method specifies.
- Number of runs. Every run, not every experiment. Standards, blanks, controls and method development draw on the same stock.
- Margin for repeats. A proportion added for runs that will have to be done again.
- Dead volume. Everything measured out but never used.
- Total mass. Volume multiplied by concentration, which gives the mass to buy.
Lines 3 and 4 are the ones that get left out, and together they are usually the difference between a series that finishes and one that stops two runs short.
Margin for repeats
Something will fail. An instrument drifts, a plate is mishandled, a result sits so far from the others that it must be repeated before it can be believed. A margin is not pessimism, it is the recognition that a series has a failure rate you already know roughly.
Set it from your own records rather than a rule of thumb. If a quarter of the runs in your last series were repeats, plan for a quarter.
There is a second reason, unrelated to failure: run short halfway and order again, and the rest of your data comes from a different lot, so lot becomes a variable in an experiment not designed to test it.
Dead volume
Dead volume is material that is measured, paid for and never used:
- the film left on the walls of a tube after the last withdrawal
- liquid retained in a pipette tip, worst at low volumes and with viscous solutions
- the remainder of an aliquot too small to be useful
- whatever sits in the dispensing path of an instrument before the first real measurement
It scales with the number of containers, not the volume in them. Splitting a stock into twelve portions creates twelve dead volumes. That is an argument for the largest portion consistent with avoiding repeated freeze thaw cycles, not for the largest portion possible.
A worked example
The figures below are assumptions made to show the arithmetic, not recommendations. Substitute your own.
A method uses 0.2 ml of a 1 mg/ml working solution per run. Twelve runs are planned. Past series have needed repeats on about a quarter of runs. The solution will be divided into eight portions, and roughly 0.05 ml is unrecoverable from each.
| Line | Working | Result |
|---|---|---|
| Volume per run | given | 0.2 ml |
| Runs planned | 12 | 2.4 ml |
| Margin for repeats, 25 per cent | 3 further runs | 0.6 ml |
| Solution actually used | 15 runs at 0.2 ml | 3.0 ml |
| Dead volume | 8 portions at 0.05 ml | 0.4 ml |
| Total solution required | 3.4 ml | |
| Mass required at 1 mg/ml | 3.4 mg |
The dead volume is 0.4 ml against 3.0 ml of useful solution, more than a tenth of the order, from a line most people never write down. The concentration calculator handles the conversions between vial mass, volume and concentration.
Choosing the vials
Three ways to cover 3.4 mg, using example sizes of 2 mg, 5 mg and 10 mg. The sizes actually available are in the catalogue.
| Option | Vials | Mass bought | Mass used | Mass not used | Reconstitutions |
|---|---|---|---|---|---|
| One large vial | 1 at 10 mg | 10 mg | 3.4 mg | 6.6 mg | 1 |
| One mid vial | 1 at 5 mg | 5 mg | 3.4 mg | 1.6 mg | 1 |
| Two small vials | 2 at 2 mg | 4 mg | 3.4 mg | 0.6 mg | 2 |
Why the large vial is not automatically cheaper
Price per milligram almost always falls as vial size rises, which makes the 10 mg vial look like the obvious choice. It is the wrong comparison. The number that matters is:
Effective cost = what you paid, divided by the mass you actually used
On that basis the 10 mg vial carries 6.6 mg bought and discarded, so it wins only if its price per milligram absorbs that. Do the division before deciding.
Timing settles the rest. A lyophilised vial sealed in its original container keeps far longer than the solution made from it. Once reconstituted, the solution has a working life, and that figure comes from your own stability records or the documentation supplied with the material, never from a guess. If the series runs longer than that, a single large vial cannot be made up in one go at all. The choice becomes discarding the remainder when the clock runs out, freezing portions and accepting the freeze thaw cost, or opening smaller vials in sequence.
Two small vials waste the least material, but they add a second reconstitution, a second set of labels, a second dead volume and, unless both come from the same lot, a second lot in the middle of your data.
A short checklist
- Count runs, not experiments, and include standards, blanks and controls.
- Add a repeat margin taken from your own records.
- Add one dead volume per container, not one per series.
- Convert to mass at the working concentration before looking at vial sizes.
- Work out the solvent volume from the same total, since solvents such as bacteriostatic water are ordered by volume and not by mass.
- Order enough of a single lot to finish the series.
- Check the duration of the series against the working life of the solution.