Orders placed by 14:00 on a business day leave Poland the same day. Free shipping from €100
Product question?Write to us
RUO

All products are chemical reagents for scientific research only. Not for consumption or use in humans or animals. Policy

In stock

N-Acetyl Epitalon Amidate modified peptide, lyophilised

€63.99 Price includes VAT

Lowest price in the last 30 days: €63.99

Research Use Only: for laboratory and scientific research only

A modified epitalon peptide supplied lyophilised in a single 5 mg vial, with a purity specification of 99% or higher and analytical documentation filed under every lot number.

Size

Secure payment: encrypted connection, processed by Stripe

Choose quantity and save

The discount is applied automatically in the cart, no code needed. All peptides and compounds count, lab supplies excluded.

Complete your research set

Total:

The volume discount is applied automatically in the cart.

Free 10 ml bacteriostatic water with orders from €50 that include a vial peptide.
Orders placed by 14:00 on a business day leave Poland the same day.

Ask about this product

  • Purity ≥ 99% (HPLC)
  • Free shipping from €100
  • Storage: −20 °C

Data sheet: N-Acetyl Epitalon Amidate

FormLyophilised powder in a vial
Also known asN Acetyl Epitalon Amidate, NAcetylEpitalonAmidate, N-Acetyl-Epitalon-Amidate
Purity≥ 99% (HPLC)
StorageLyophilised: −20 °C, protected from light. After reconstitution: 2 to 8 °C.

N-Acetyl Epitalon Amidate in the laboratory

Identification

N-Acetyl Epitalon Amidate is catalogued under cellular ageing as a lyophilised peptide, supplied in one fill size of 5 mg per vial at a purity specification of 99% or higher. Its name records two terminal modifications made to the epitalon peptide: an N-acetyl group on the amino end of the chain and an amide in place of the free acid at the carboxyl end. Modifications of this kind alter the charge that each end of the chain carries, so the behaviour of the material in a given solvent is not assumed to match that of the parent peptide. For that reason it is catalogued as a separate entry, and the solvent should be chosen with a small trial in mind.

Analytical control

Purity is determined by reversed phase high performance liquid chromatography. The main peak is integrated against the full chromatogram, related substances and process residues are separated from it, and the result is read against the specification of 99% or higher. Identity is established by mass spectrometry, with the measured mass checked against the structure the name describes. Both results are filed against the lot number printed on the vial label.

Reconstitution and solubility

Bring the sealed vial to room temperature before opening it, since a cold cake draws condensation onto the powder. Add the solvent slowly down the inner wall of the vial, never directly onto the solid, then swirl gently or let the vial rest until the powder has dissolved. Bacteriostatic water is the usual choice for a stock that will be drawn from repeatedly, sterile water for a solution used at once, and a dilute acetic acid solution where the cake is slow to clear in water alone.

Vial size Solvent added Resulting concentration
5 mg 1 mL 5 mg/mL
5 mg 2 mL 2.5 mg/mL

The first row gives the most concentrated stock available from the vial, and the second suits protocols that call for a more dilute working solution.

Storage and stability

Keep the sealed solid at minus 20 degrees Celsius, shielded from light, until it is needed. Once the peptide has been taken up, the solution goes to 2 to 8 degrees Celsius. Dividing the solution into working portions as it is made means that each draw leaves the remaining stock unopened, and a thawed portion is better used than returned to the freezer. Let a frozen vial come up to room temperature before the stopper is removed.

Use in the laboratory

The material is supplied for in vitro experiments and for use as a reference material. The catalogue places it in cellular ageing research, and this entry is listed for laboratories working in that area. Difania supplies the peptide together with the analytical documentation held for its lot. It does not advise on experimental design, and it does not interpret results obtained with the material.

Safety and handling

Wear gloves and eye protection whenever the vial is open or a solution is being transferred, and handle the dry solid within the containment your laboratory applies to fine powders. Residues, rinses and used labware are disposed of under the rules of your institution and the local regulations that bind it. This is a laboratory chemical and not a medicinal product, food, supplement or cosmetic. It is not for consumption, and it is not for administration to humans or animals.

Lot documentation

Each vial carries a lot number on its label. That number is the key to the records Difania holds for the material, so quote it when you make a request and the analytical documentation for the lot can be retrieved. Record the lot number together with the date the vial was opened and the solvent used, so that every later observation can be traced back to the fill it came from.

N-Acetyl Epitalon Amidate: questions from the lab

Which solvent should I choose for this peptide?

Bacteriostatic water for a stock that will be drawn from over several sessions, sterile water for a solution made for one sitting, and a dilute acetic acid solution where the cake clears slowly in water. Because the terminal modifications change the charge at each end of the chain, run a small trial before committing a full vial.

How much solvent goes into the 5 mg vial?

Adding 1 mL gives 5 mg/mL, which is the most concentrated working solution the vial allows at that volume. Adding 2 mL gives 2.5 mg/mL for a more dilute stock. Add the solvent down the inner wall of the vial rather than onto the powder.

How should the vial be stored before and after reconstitution?

Keep the sealed solid at minus 20 degrees Celsius and away from light. Let the vial reach room temperature before opening it. Once the peptide is in solution, hold it at 2 to 8 degrees Celsius and divide it into portions as it is prepared.

What analytical documentation is held for a lot?

Purity is recorded by reversed phase HPLC against the specification of 99% or higher, and identity by mass spectrometry. Both sets of data are filed under the lot number printed on the label, so quote that number when you request the documentation.

How is the material dispatched?

Orders placed by 14:00 on a business day are dispatched the same day. The vial is packed as a laboratory chemical, and its lot number is recorded on the outer packing so that it matches the documentation supplied with it.

Rate this product

Click a star: from 1 to 5.

Related reagents